AS-208 8-zone address module and zone expansion module for intrusion alarm panels

8-zone Address Module

Eight-Zone Wired Expansion for AS-9000 Intrusion Alarm Systems

Type: AS-208

→ GET QUOTATION

Related: Alarm Panel

The Athenalarm AS-208 is an eight-zone address module designed to connect additional wired alarm detectors to AS-9000 series intrusion alarm control panels through bus communication.

With eight wired detector zones, support for normally open (NO) and normally closed (NC) alarm detectors, and address-based integration, the AS-208 provides an expansion option for compatible intrusion alarm installations.

The module includes a physical address-setting switch, keypad-based bus-device discovery, and dedicated indicators for power, arming, alarm, and communication status. It also provides documented connections for a siren and an armed-status indicator light.

Designed for B2B procurement, the AS-208 is intended for security product importers, distributors, wholesalers, and system integrators evaluating additional wired detection capacity for AS-9000 installations.

Compatibility Note: The AS-208 is suitable for AS-9000 series alarm control panels.

[GET QUOTATION →]

Contact Athenalarm with your required quantity, control panel model, and project requirements to obtain a quotation and confirm technical suitability.

1. Eight-Zone Expansion for Wired Intrusion Detection

The AS-208 addresses a specific system integration requirement: connecting additional wired alarm detectors to a compatible AS-9000 series intrusion alarm control panel.

Rather than functioning as a standalone alarm controller, the module operates as an expansion component within the supported alarm system.

Its eight wired zones allow system integrators to plan additional detector connections using the compatible control panel’s bus architecture. Each zone can accommodate a normally open or normally closed alarm detector, subject to the requirements of the overall system.

The module also supports address-based identification and keypad-based bus-device discovery. These functions help installers identify expansion devices during system commissioning and when the module configuration changes.

For procurement teams, the principal evaluation criteria are zone capacity, control panel compatibility, electrical requirements, addressing configuration, and the availability of appropriate technical documentation.

1.1 Main Functions

  • Adds eight wired alarm detector zones to a compatible AS-9000 installation.
  • Supports normally open (NO) and normally closed (NC) alarm detector connections.
  • Communicates with the control panel through the system bus.
  • Provides address configuration through an address-setting switch.
  • Supports bus-device discovery through the control panel keypad.
  • Provides power, arm, alarm, and communication status indicators.
  • Includes connections for a siren and an armed-status indicator light.

The module’s compatibility boundary and electrical requirements should be checked before incorporating it into a project design.

2. Key Features for Security System Integrators

2.1 Eight Wired Detector Zones

The AS-208 provides eight wired alarm detector zones through one expansion module.

This capacity is relevant to projects that require additional wired detection points within an existing or planned AS-9000 intrusion alarm system.

For distributors and project integrators, the eight-zone configuration provides a defined basis for estimating module quantities and reviewing the proposed system architecture.

2.2 NO/NC Detector Compatibility

The module supports normally open (NO) and normally closed (NC) alarm detector contacts.

This specification helps integrators evaluate whether the detector interfaces required for a project are compatible with the documented module inputs.

The use of NO or NC contacts does not, by itself, establish compatibility with every detector type or wiring arrangement. Final selection should follow the requirements of the connected detector and AS-9000 system.

2.3 Bus Communication and Address-Based Integration

The AS-208 connects to an AS-9000 series alarm control panel through bus communication.

An address code setting switch provides address-based configuration, while the control panel’s Search Bus Device function supports the discovery of connected expansion modules.

2.4 Power, Arm, Alarm, and Communication Indicators

The module provides four dedicated status indicators:

IndicatorDocumented Function
PowerIlluminates when power is normal
ArmIlluminates when the alarm system is armed
AlarmIlluminates when the alarm system is in an alarm condition
CommunicationBlinks when communication is normal

These indicators provide local visual information that can assist technicians when checking the module’s operating status during installation, commissioning, and troubleshooting.

2.5 Siren and Armed-Status Indicator Connections

The AS-208 includes separate connections for a siren and an armed-status indicator light.

  • Alarm connection: Connects to a siren that is activated when the module alarms.
  • Arm connection: Connects to an indicator light that indicates the alarm system’s armed status.

Confirm the output ratings and wiring requirements with Athenalarm before selecting or connecting a siren or indicator light.

3. Technical Specifications

The following specifications are based on the supplied AS-208 product manual. Items requiring additional clarification are identified separately.

ParameterSpecification
Product ModelAS-208
Product Name8-Zone Address Module
Product TypeWired alarm zone expansion module
Main FunctionConnects remote wired alarm detectors to a compatible alarm control panel
Zone Capacity8 wired zones
Supported Detector ContactsNormally open (NO) / normally closed (NC)
Compatible Control PanelAS-9000 series alarm control panels
CommunicationBus communication
Address SettingAddress code setting switch
Bus-Device DiscoveryControl panel keypad: Device Management → Search Bus Device
Operating VoltageDC 10–24 V
Working Current30 mA
Dimensions130 × 80 × 26 mm (L × W × D)
Weight200 g
Operating Temperature−10°C to +50°C
Humidity0–85%
Status IndicatorsPower, Arm, Alarm, Communication
Standard MOQ5 pieces
Sample AvailabilityYes
Standard Production Lead Time10 days
Warranty Period1 year, subject to the confirmed warranty conditions
OEM/ODM AvailabilityAvailable; scope and commercial conditions require confirmation
OEM MOQ200 pieces
OEM/ODM Lead Time15 days for confirmed customization requirements

4. Addressing and Bus-Device Discovery

Correct addressing is important when an AS-208 is incorporated into an AS-9000 alarm system.

4.1 Address Code Configuration

The AS-208 uses an address code setting switch.

The supplied user manual includes an address-to-zone allocation table. Examples from that table include:

Address CodeDocumented Zone Range
0400–407
1408–415
2416–423
1991992–1999

Each listed range contains eight zone numbers.

For the complete address-switch settings and corresponding zone allocations, consult the AS-208 8-zone Address Module User Manual.

Installation requirement: Before commissioning a multi-module installation, verify that the configured addresses and resulting zone allocations are correct. Obtain confirmation from Athenalarm if duplicate addresses are detected or the expected zone numbering differs from the documented table.

4.2 Keypad-Based Bus-Device Discovery

The supplied manual describes the following discovery process:

  1. Connect the module according to the applicable wiring instructions.
  2. Access the alarm control panel keypad.
  3. Open Device Management → Search Bus Device.
  4. Allow the control panel to search for bus expansion modules and establish communication.
  5. Repeat the search after a module is added, removed, or replaced.

This procedure is documented for the compatible AS-9000 system.

5. Wiring Connections and Installation Considerations

ConnectionDocumented Function
Green, yellow, blackBus signal connections to the corresponding control panel signal lines
Power + and −Positive and negative power connections
Alarm and −Siren connection, activated when the module alarms
Arm and −Indicator-light connection for armed-status indication

5.1 Before Installation

Review the current AS-208 manual and the applicable AS-9000 bus-wiring instructions before connecting the module.

Particular attention should be given to the following points:

  • Confirm the power-terminal labeling and applicable supply voltage.
  • Verify the bus connections against the compatible control panel documentation.
  • Confirm the correct address-switch setting and resulting zone allocation.
  • Establish the maximum permitted loads for the siren and armed-status indicator connections.
  • Follow the applicable instructions for connecting NO or NC alarm detectors.
  • Repeat bus-device discovery after adding, removing, or replacing a module.

The supplied documentation does not establish maximum bus length, all permitted cable configurations, or output load limits. These parameters should not be assumed when preparing an installation design.

Technical resources:

6. Applications

The AS-208 is intended for wired intrusion alarm installations that use AS-9000 series alarm control panels.

6.1 Commercial Buildings and Retail Premises

For compatible installations requiring additional wired detector zones across offices, retail premises, and commercial buildings.

6.2 Warehouses and Industrial Facilities

For projects using AS-9000 alarm control panels where additional wired detector connections are required. The installation must remain within the module’s documented electrical and environmental limits.

6.3 Security System Integration Projects

For system integrators expanding the wired detection capacity of a compatible alarm installation.

The eight-zone capacity, NO/NC detector compatibility, address-setting function, and bus-device discovery process provide relevant information for technical planning.

6.4 Alarm System Distribution

For importers, distributors, and wholesalers sourcing alarm control panel accessories for compatible system portfolios.

The AS-208 can be evaluated as an accessory for customers purchasing or deploying AS-9000 series alarm control panels.

6.5 Existing AS-9000 Installations

For installations requiring additional wired detector connections, subject to confirmation of the existing panel configuration, available addressing capacity, and applicable system documentation.

Application limitation: The product’s documented compatibility is limited to the AS-9000 series.

7. OEM/ODM and Procurement Information

Athenalarm accepts OEM/ODM inquiries for the AS-208. The specific customization scope and applicable conditions must be confirmed before an order is finalized.

The following commercial information is available for initial procurement planning.

Procurement ItemCurrent Information
Standard MOQ5 pieces
Sample AvailabilityYes
Standard Production Lead Time10 days
OEM/ODM AvailabilityYes; confirm the specific service required
OEM MOQ200 pieces
OEM/ODM Lead Time15 days for confirmed customization requirements
PricingContact Athenalarm for a quotation
Warranty Period1 year, subject to confirmed coverage conditions
Technical SupportOnline guidance

7.1 OEM/ODM Requirements

Different distributors and importers may have different requirements for branding, product labeling, packaging, and documentation.

The availability and conditions of individual customization options for the AS-208 should be confirmed separately.

The stated lead times are for preliminary planning. Confirm the final production schedule, customization scope, and delivery arrangements when requesting a quotation.

7.2 Request a Quotation

To help Athenalarm evaluate your requirements, include:

  • Required order quantity.
  • Your business type: importer, distributor, wholesaler, or system integrator.
  • Intended application.
  • Control panel model and relevant technical requirements.
  • Any OEM/ODM requirements.

Athenalarm can then confirm product suitability and the applicable commercial terms.

8. Quality Control, Warranty

8.1 Quality Control

AS-208-specific inspection procedures, test coverage, and acceptance criteria: 100% inspection

8.2 Warranty and After-Sales Support

The warranty period is one year, excluding damage caused by human action.

Online technical guidance is available. Buyers should provide the control panel model, installation details, and a clear description of the technical issue when requesting assistance.

9. Downloads and Technical Resources

Technical documentation can help purchasing teams assess compatibility and enable engineering teams to review installation requirements before deployment.

The following resources are relevant to the AS-208.

DocumentPurposeLink
AS-208 User ManualProduct specifications, wiring, indicators, address settings, and zone allocationDownload AS-208 8-zone Address Module User Manual
AS-9000 Series Alarm Control PanelCompatible control panel and system informationView AS-9000 Series
AS-9000 Bus Wiring InstructionsControl panel bus-wiring referenceBus Wiring Instructions

Additional Athenalarm products that are relevant to a compatible alarm installation include:

These products have different functions. Select the appropriate module according to the required zone capacity, output functions, and confirmed system compatibility.

10. Frequently Asked Questions

10.1. Product and Procurement FAQ

Q1. What is the AS-208 8-zone address module?

The AS-208 is an eight-zone wired expansion module designed to connect remote alarm detectors to AS-9000 series intrusion alarm control panels through bus communication.

It supports NO/NC alarm detector contacts and provides address-based integration within the compatible system.

Q2. What is the minimum order quantity?

The standard MOQ is 5 pieces.

For an OEM/ODM order, the stated MOQ is 200 pieces. Confirm the applicable conditions according to the required customization scope.

Q3. Are samples available?

Yes. Confirm the sample price, shipping arrangements, and availability when contacting Athenalarm.

Q4. What is the production lead time?

The standard production lead time is 10 days.

The stated lead time for confirmed OEM/ODM requirements is 15 days. The final schedule should be confirmed according to the order quantity, customization scope, and order requirements.

Q5. Does Athenalarm support OEM/ODM orders?

Yes. Athenalarm accepts OEM/ODM inquiries for the AS-208.

The specific branding, packaging, labeling, or documentation options available for this model should be confirmed individually. The stated OEM MOQ is 200 pieces, with a 15-day customization lead time for confirmed requirements.

Q6. What is the warranty period?

The warranty period is one year, excluding damage caused by human action.

Q7. Is technical support available?

Online technical guidance is available.

For more effective assistance, provide the control panel model, module address, relevant wiring information, and a description of the issue.

Q8. How can I obtain pricing?

Contact Athenalarm for a quotation.

Include your required quantity, intended application, and any OEM/ODM requirements so that the applicable commercial terms can be confirmed.

10.2 Technical FAQ

Q1. Which alarm control panels are compatible with the AS-208?

The AS-9000 series alarm control panels are compatible with the AS-208.

Q2. How many wired detectors can the AS-208 connect?

The module provides eight wired zones and supports normally open (NO) and normally closed (NC) alarm detector contacts.

The selected detectors and wiring arrangements must also meet the requirements of the compatible alarm system.

Q3. How does the AS-208 communicate with the control panel?

The AS-208 uses bus communication.

The supplied manual identifies green, yellow, and black as the bus signal connections, corresponding to the respective signal lines on the control panel.

Q4. How does the control panel discover the module?

After completing the wiring, access the control panel keypad and select:

Device Management → Search Bus Device

The control panel searches for connected bus expansion modules and establishes communication.

The search should be repeated after adding, removing, or replacing a module.

Q5. How are the module addresses and zone numbers assigned?

The AS-208 has an address code setting switch.

The supplied manual includes an address-to-zone table. For example, address code 0 corresponds to zones 400–407, while address code 1 corresponds to zones 408–415.

Consult the current AS-208 manual for the complete switch settings and zone allocation.

Confirm the expected address and zone allocation before commissioning a system in which duplicate addresses are detected.

Q6. What do the status indicators mean?

The AS-208 provides four indicators:

  • Power: Illuminates when power is normal.
  • Arm: Illuminates when the alarm system is armed.
  • Alarm: Illuminates when the alarm system is in an alarm condition.
  • Communication: Blinks when communication is normal.

These indicators provide local information about the module’s operating status.

Q7. Can the AS-208 activate a siren?

It provides an alarm connection intended to activate a siren when the module alarms.

Q8. Can the AS-208 provide an armed-status indication?

Yes. It provides an Arm connection intended to drive an indicator light. The light provides an indication when the alarm system is armed.

Confirm the electrical requirements of the connected indicator before installation.

Q9. What power supply does the AS-208 require?

The supplied manual specifies an operating-voltage range of DC 10–24 V.

Confirm the actual terminal labeling and permitted supply requirements against the current product documentation before wiring.

Q10. What are the operating temperature and humidity limits?

The manual specifies an operating temperature range of −10°C to +50°C and a humidity range of 0–85%.

Q11. Is the AS-208 suitable for outdoor installation?

The AS-208 can only be installed outdoors after proper weatherproofing and sun-protection measures have been implemented.

13. Request a Quotation from Athenalarm

13.1 Source AS-208 8-Zone Address Modules for Your Security Projects

Are you evaluating an eight-zone wired expansion module for an AS-9000 series intrusion alarm control panel?

The Athenalarm AS-208 provides eight wired alarm detector zones, NO/NC detector compatibility, bus-based system integration, address-setting functionality, and dedicated operating-status indicators.

For importers, distributors, wholesalers, and system integrators, the key purchasing considerations are whether the module fits the intended alarm system, whether the electrical and addressing requirements are suitable, and whether the available commercial terms meet project or distribution needs.

Contact Athenalarm to confirm technical suitability and obtain a quotation based on your requirements.

13.2 Help Us Evaluate Your Requirements

When submitting an inquiry, please include:

  • Company name and destination country.
  • Business type: importer, distributor, wholesaler, or system integrator.
  • Estimated order quantity.
  • Intended application and control panel model.
  • Relevant compatibility or installation questions.
  • Any OEM/ODM requirements for evaluation.

[GET QUOTATION →]

Contact Athenalarm to discuss the AS-208 8-zone address module for your project or distribution requirements.

WhatsApp Chat with us