AS-211 single-zone address and output module, zone expansion component for intrusion alarm control panels.

Single-zone Address & Output Module

Single-Zone Address & Output Module for AS-9000 Intrusion Alarm Systems

Type: AS-211

→ GET QUOTATION

Related: Alarm Panel

The AS-211 is a bus-connected expansion module for the Athenalarm AS-9000 series alarm control panel. It adds one normally open (NO) / normally closed (NC) alarm detector zone to the system and provides local output functions — a 12V/1A power output and an NO/NC switch output — for alarm equipment and linkage devices such as sirens, flashing lights and cameras.

Capability strip:
1 Detector Zone · NO/NC Input · AS-9000 Bus Communication · 12V/1A Power Output · NO/NC Switch Output · Address Code Setting

Designed for: Importers · Distributors · Wholesalers · System Integrators · Intrusion Alarm Project Suppliers

[ GET QUOTATION ]

Quick Procurement Snapshot

ItemInformation
MOQ10 pcs
SampleAvailable
Standard Lead Time10 days
OEMAvailable (logo / labeling / packaging / documentation)
OEM MOQ200 pcs
OEM Lead Time15 days
Trade TermsEXW / FOB / CIF
Warranty1 year

1. AS-211 Overview

The AS-211 combines single-zone address expansion with local output linkage in one compact module.

A remote NO or NC alarm detector connects to the AS-211, which communicates with the AS-9000 alarm control panel over the system bus. The connected detector is assigned an individual zone within the AS-9000 system. When the AS-9000 control panel processes an alarm condition on that zone, the AS-211 can additionally provide a power output for local alarm equipment or a switch signal for linked security equipment.

System architecture

Remote Alarm Detector → AS-211 → AS-9000 Bus → AS-9000 Alarm Control Panel
AS-211 → 12V/1A Output → Siren / Flashing Light
AS-211 → NO/NC Switch Output → Camera / Other Linkage Equipment

This architecture positions the AS-211 as more than a basic address module: it combines detector input, AS-9000 bus addressing, and output/linkage capability within a single device. Outputs are triggered and controlled within the AS-9000 system; the module does not operate as an independent decision-making device.

2. Input, Output & Bus Architecture

2.1 Single-Zone Detector Input

The AS-211 connects one alarm detector per module. Supported input types:

  • Normally Open (NO)
  • Normally Closed (NC)

This allows the module to interface with compatible wired intrusion detectors within the AS-9000 system.

2.2 AS-9000 Bus Communication

The AS-211 communicates with the AS-9000 series alarm control panel through the system bus (Green/Yellow signal lines). A communication indicator provides a simple operating-status reference:

  • Blinking = normal module communication

2.3 12V/1A Power Output

The AS-211 provides a 12V / 1A power output, which can be used to drive compatible alarm equipment such as:

  • Sirens
  • Flashing lights
  • Other compatible 12V alarm equipment

2.4 NO/NC Switch Output

The AS-211 also provides a separate NO/NC switch output for equipment linkage, such as:

  • Camera triggering
  • Video linkage
  • Other compatible security equipment accepting an NO/NC input

3. Addressing & AS-9000 Bus Device Management

3.1 Address Code Setting

The AS-211 uses an address code setting switch for assignment within the AS-9000 system. The module occupies a zone within the following range:

Zone Range: 100–299
Zone Number = Address Code + 100

3.2 Automatic Bus Device Search

After the AS-211 is wired into the system, installers can use the AS-9000 keypad menu:

Device Management → Search Bus Device

The control panel automatically searches the bus for connected expansion modules and establishes communication, then displays the number of devices found. The search should be repeated whenever modules are:

  • Added
  • Removed
  • Replaced

3.3 Duplicate-Code Handling

Each AS-211 module carries its own address code. If more than one module is assigned the same code, the AS-9000 control panel can automatically reassign the duplicated module, beginning from code 399. This mechanism is intended to assist with duplicate-code situations during system expansion or module replacement, rather than functioning as a permanent hardware serial number.

4. Wiring & Connection

Wire PairConnection
Red / BlackPositive / negative power supply
Green / YellowAS-9000 bus signal — positive / negative
Blue / WhiteDetector connection — Normally Closed (NC) / Common (COM)

Output wiring

Wire PairFunction
Red / YellowOutput voltage connection for compatible alarm equipment (e.g., siren). Per the supplied documentation, this output can directly drive a siren.
Yellow / BlackSwitch-signal output for linkage equipment (e.g., camera input)

Installers should confirm the electrical requirements of connected detectors and output equipment before deployment, in accordance with the AS-211 wiring documentation.

5. AS-211 vs. AS-201

Athenalarm offers both the AS-201 Single-zone Address Module and the AS-211 Single-zone Address & Output Module within the AS-9000 accessory range.

FunctionAS-201AS-211
Single-zone expansion✓✓
AS-9000 bus communication✓✓
Address code setting✓✓
NO/NC detector input✓✓
12V/1A alarm-equipment output—✓
NO/NC switch output—✓
Siren / flashing-light triggering—✓
Camera / video linkage—✓

Selection guidance: Choose the AS-201 when the project requires basic single-zone address expansion only. Choose the AS-211 when the project also requires local alarm output or equipment linkage (siren, flashing light, camera).

6. Technical Specifications

ParameterAS-211 Specification
Product TypeSingle-zone Address & Output Module
ModelAS-211
Dimensions60 × 16 × 10 mm
Weight10 g
Working VoltageDC 10–24V
Working Current10 mA
Operating Temperature-10°C to +50°C
Humidity0–85%
Detector Input1 zone
Detector TypeNormally Open (NO) / Normally Closed (NC)
CommunicationAS-9000 alarm control panel bus
AddressingAddress code setting switch
Zone Range100–299
Zone MappingZone number = address code + 100
Power Output12V / 1A
Switch OutputNormally Open / Normally Closed signal
Communication IndicatorBlinking when communication is normal
Device SearchSupported via AS-9000 keypad menu
Warranty1 year

7. Applications for AS-9000 Intrusion Alarm Systems

  • Commercial intrusion alarm system zone expansion
  • Wired security detector integration
  • AS-9000 system expansion (additional detector zones)
  • Siren / flashing-light linkage for on-site alarm response
  • Camera / video linkage for alarm-triggered recording
  • System integration projects requiring both detector input and output linkage within one module

Note: Compatibility is established for the Athenalarm AS-9000 series alarm control panel. Compatibility with third-party or unrelated addressable alarm systems is not established and should not be assumed.

8. MOQ, Lead Time & OEM Options

8.1 Procurement Information

Procurement ItemInformation
MOQ10 pcs
Sample AvailabilityAvailable
Standard Lead Time10 days (subject to order quantity and production schedule)
Production Capacity5000 pieces per month
PackagingTape-sealed packaging
Payment Terms100% T/T in advance
Trade TermsEXW / FOB / CIF
Warranty1 year
Technical SupportAvailable — see Section 9
After-sales SupportAvailable — see Section 9

*Commercial terms are provided as current reference information and are subject to confirmation at the time of quotation.

8.2 Standard OEM / Private-Label Options

Athenalarm can accommodate standard OEM / private-label requests, including:

  • Logo
  • Product labeling
  • Packaging
  • Documentation
OEM ItemInformation
OEM AvailabilityYes
OEM MOQ200 pcs
OEM Lead Time15 days
Hardware CustomizationNot currently offered
Firmware / Software CustomizationNot currently offered

This standard OEM scope allows faster turnaround without custom engineering or tooling delays.

9. Documentation & Technical Support

9.1 Documentation

9.2 Warranty

Warranty period: 1 year.

9.3 Technical Support

Athenalarm can provide support for:

  • AS-9000 compatibility confirmation
  • Wiring and installation guidance
  • Project configuration discussion
  • OEM / private-label requirements

10. Product FAQ

Q1: What is the AS-211?
The AS-211 is a single-zone address & output module for the AS-9000 series alarm control panel, combining detector input, bus addressing and alarm/linkage output in one device.

Q2: What is the difference between the AS-201 and AS-211?
The AS-201 provides basic single-zone address expansion. The AS-211 adds a 12V/1A alarm-equipment output and an NO/NC switch output for siren, flashing-light or camera linkage. See Section 5.

Q3: What is the MOQ?
10 pcs.

Q4: Is OEM / private-label service available?
Yes, for logo, labeling, packaging and documentation. Hardware and firmware customization are not currently offered.

Q5: What is the standard lead time?
10 days standard, subject to order quantity and production schedule.

Q6: What warranty is provided?
1 year.

11. Technical & Integration FAQ

Q1: Which control panel does the AS-211 support?
The AS-211 is designed to communicate with the Athenalarm AS-9000 series alarm control panel through the system bus.

Q2: How many detectors can one AS-211 connect?
One alarm detector zone, supporting an NO or NC input.

Q3: Does it support both NO and NC detectors?
Yes, the AS-211 supports both Normally Open (NO) and Normally Closed (NC) detector connections.

Q4: Can the AS-211 drive a siren?
Yes. The documented 12V/1A power output can be connected to compatible alarm equipment such as a siren.

Q5: Can the AS-211 trigger a camera?
The AS-211 provides an NO/NC switch output that can be connected to the input of compatible equipment, such as a camera, for video linkage.

Q6: How is the AS-211 addressed?
Via an address code setting switch. Supported zone range: 100–299. Zone number = address code + 100.

Q7: How does the control panel discover the AS-211?
Through the AS-9000 keypad menu: Device Management → Search Bus Device. Re-search is required after adding, removing or replacing modules.

Q8: What happens with a duplicate address code?
Per the supplied documentation, if more than one module shares the same code, the AS-9000 control panel can automatically reassign the duplicated module beginning from code 399.

Q9: Can the AS-211 work with third-party addressable alarm panels?
Compatibility is established only with the Athenalarm AS-9000 series alarm control panel. Compatibility with third-party addressable protocols is not established and should not be assumed without technical verification.

12. Request a Quotation

Looking for a Single-Zone Address & Output Module for Your AS-9000 Intrusion Alarm Project?

The AS-211 combines single-zone detector input, AS-9000 bus addressing, and 12V/1A alarm-equipment / NO-NC switch output linkage in one compact module — suitable for importers, distributors, wholesalers and system integrators expanding AS-9000 intrusion alarm deployments.

To receive a project-specific quotation, please provide:

  • Required quantity
  • AS-9000 system configuration
  • Detector type (NO/NC)
  • Output equipment (siren, flashing light, camera, etc.)
  • OEM / private-label requirements
  • Packaging requirements

[ GET QUOTATION ]

For: Importers · Distributors · Wholesalers · System Integrators · Intrusion Alarm Project Suppliers

WhatsApp Chat with us